Beam Spec Sheet

Beam operates autonomously with passive technology and requires almost zero behavioral changes from occupants. Beam is ideal for use in areas such as open offices, reception areas, and larger conference rooms. This upper-room ultraviolet germicidal irradiation (UVGI) device works in occupied spaces to inactivate airborne microbes and help disinfect indoor air, safely

Efficacy

Methicillin-Resistant Staphylococcus epidermidis (MRSE) (Bacterium)99.99% inactivation in 6 minutes using Upper Room UVGI
Klebsiella aerogenes (Bacterium)99.99% inactivation in 11 minutes using Upper Room UVGI
T1 (Virus)99.99% inactivation in 14 minutes using Upper Room UVGI
SARS-CoV-2 (Virus)99.99% inactivation in 30 minutes using Upper Room UVGI

Germicidal Light Engine

UV Source4 Proprietary LED bars, 12 LEDs per bar
Rated LED Life10,000 hrs, up to 3 years under normal operating conditions
WavelengthNominal 265 nm (range 260-270 nm)
Coverage AreaUp to 750 square feet
Added Equivalent Air Exchanges12+ eACH

Controls

On UnitDevice status indicator, on/off switch
Remote OperationWeb interface (R-Zero Connect)
Auto OperationTouchless power-on when room is occupied
ConnectivityWiFi (2.4 GHz)

Electrical

Input Voltage120-240 VAC
Current1.6A (at 120 VAC)
Typical Power Consumption120W
Max Power Consumption200W
Power ConnectionStandard 3-prong wall outlet (IEC C14)

Physical

Dimensions77 inches tall, 16 inches wide
Weight25 lb
MountingWall or Suspended from Ceiling
Minimum Mounting Height7 feet from floor

Environmental

Indoor/OutdoorIndoor only
Altitude0-3000m
Temperature10-40C
Relative Humidity10-90%

Safety

Motion Sensors2 long-range PIR sensors in the irradiance zone
1 long range PIR sensor in occupied zone
Physical FeaturesBaffle under LEDs to direct light and keep occupant exposure below limits to direct UV-C light

Regulatory

UL 1598, UL 8750, CSA C22.2 No. 250Passed March 2022
FCC Part 15CPassed August 2021